لا نعمل pemit ل manpower support
أو
Vendor support
لكن ل support service / roof load test
ممكن
لا نعمل pemit ل manpower support
أو
Vendor support
لكن ل support service / roof load test
ممكن
وقت شغل ووقت الايزولشن كل فالف مبند ما عدا drain
والعكس في de isolation
للعلم عادي اوبن للدرين يكون أكثر من واحد رايح على wat pit
T-9093 scope of Work
Unbolting Flange Joints:
1. 12” X 150# Flange Joints Unbolting – 6 no’s
2. 10” X 150# Flange Joints Unbolting – 3 no’s
3. 6” X 150# Flange Joints Unbolting – 4 no’s
4. 4” X 150# Flange Joints Unbolting – 4 no’s
5. 3” X 150# Flange Joints Unbolting – 2 no’s
6. 1” X 150# Flange Joints Unbolting – 3 no’s
7. 24” X 150# Flange Joints Unbolting(MH) – 3 no’s
8. 20” X 150# Flange Joints Unbolting(MH) – 1 no’s
9. 12” X 150# Flange Joints Unbolting (MH Vent) – 1 no’s
Existing Valve Remove Set aside:
1. 12” X 150# Existing valve Remove set aside – 2 no’s
2. 10” X 150# Existing valve Remove set aside – 1 no’s
3. 6” X 150# Existing valve Remove set aside – 2 no’s
4. 4” X 150# Existing valve Remove set aside – 2 no’s
5. 3” X 150# Existing valve Remove set aside – 1 no’s
6. 1” X 150# Existing valve Remove set aside – 2 no’s
Existing Pipe Spool Remove Set aside:
1. 12” X Sch 80 Existing Pipe Spool Remove set aside – 2.5 MTR
2. 10” X Sch 80 Existing Pipe Spool Remove set aside – 1 MTR
3. 6” X Sch 80 Existing Pipe Spool Remove set aside – 3 MTR
4. 4” X Sch 80 Existing Pipe Spool Remove set aside – 16 MTR
5. 3” X Sch 80 Existing Pipe Spool Remove set aside – 1.5 MTR
Install Blind:
1. 12” X 150# Install Blind – 2 no’s
2. 10” X 150# Install Blind – 2 no’s
3. 6” X 150# Install Blind – 4 no’s
4. 4” X 150# Install Blind – 2 no’s
5. 3” X 150# Install Blind – 2 no’s
6. 1” X 150# Install Blind – 2 no’s
Boxup & De-spading
Remove Blind:
1. 12” X 150# Remove Blind – 2 no’s
2. 10” X 150# Remove Blind – 2 no’s
3. 6” X 150# Remove Blind – 4 no’s
4. 4” X 150# Remove Blind – 2 no’s
5. 3” X 150# Remove Blind – 2 no’s
6. 1” X 150# Remove Blind – 2 no’s
Pipe Spool Re-install:
1. 12” X Sch 80 Existing Pipe Spool Re-install – 2.5 MTR
2. 10” X Sch 80 Existing Pipe Spool Remove Re-install – 1 MTR
3. 6” X Sch 80 Existing Pipe Spool Remove Re-install – 3 MTR
4. 4” X Sch 80 Existing Pipe Spool Remove Re-install – 16 MTR
5. 3” X Sch 80 Existing Pipe Spool Remove Re-install – 1.5 MTR
Existing Valve Re-install:
1. 12” X 150# Existing valve Re-install – 2 no’s
2. 10” X 150# Existing valve Re-install – 1 no’s
3. 6” X 150# Existing valve Re-install – 2 no’s
4. 4” X 150# Existing valve Re-install – 2 no’s
5. 3” X 150# Existing valve Re-install – 1 no’s
6. 1” X 150# Existing valve Re-install – 2 no’s
Bolt-up Flange Joints:
1. 12” X 150# Flange Joints Bolt-up – 6 no’s
2. 10” X 150# Flange Joints Bolt-up – 3 no’s
3. 6” X 150# Flange Joints Bolt-up – 4 no’s
4. 4” X 150# Flange Joints Bolt-up – 4 no’s
5. 3” X 150# Flange Joints Bolt-up – 2 no’s
6. 1” X 150# Flange Joints Bolt-up – 3 no’s
7. 24” X 150# Flange Joints Bolt-up (MH) – 3 no’s
8. 20” X 150# Flange Joints Bolt-up (MH) – 1 no’s
9. 12” X 150# Flange Joints Bolt-up (MH Vent) – 1 no’s
فيها unit rate ما يوقع dsr
Dsr سوينها
ما يمشي في QS
سابوا
كله شغله ندخل مالها code عشان unit rate
فارق بين manpower supplay و unit rate
مان بوار ١٥ الف و يونت ريت ٣٥٠ ريال فارق كبير
التسعسرات من QS
كود مع الشغله مع السعر
الحسبه ب الأوزان في ميكانيك
بولتنج انشل وشدرل الحسبه
وكلاس مال بايب
شد يونت ريت طول في العرض
Lifting
يحسبوا الوزن لانه unit rate
لفتنج عادي manpower supplay
Code مختيز حال سعر
PD0 plannerيقدر يغيره
Cost estminstion ممكن يزيد ار يقل تدخل عمليات
دخل كوود ويزيد